1-34.
The device that is inserted in the
heat exchangers water box to
concentrate electrolytic action to
it vice to the metal of the heat
exchangers tubes is made of what
material (s)?
1.
Zinc cathode
2.
Zincs only
3.
Zinc anode only
4.
Both 2 and 3 above
1-35.
Who is the best qualified person on
board to determine the overall
condition of the cooling system?
1.
Engineering officer
2.
Electronics material officer
3. Systems test officer
4.
Ships maintenance technician
1-36.
The expansion tank sight glass
1-37.
1-38.
1-39.
1-40.
should normally read in what range?
1.
1/4 to 1/2 full
2.
1/3 to 2/3 full
3.
1/2 to 3/4 full
4.
2/3 to 4/5 full
The low-level alarm switch is
usually set at 20 percent of tank
capacity. The alarm will initially
sound when the distilled water
level reaches which of the
following levels?
1.
5 percent of full
2.
10 percent of full
3. 15 percent of full
4. 20 percent of full
What term best describes the word
makeup water?
1.
Distilled water
2.
Seawater
3.
Potable water
4.
Chilled water
When, if ever, may potable water be
used in electronic cooling systems?
1. After chloride is added
2. Only as makeup water
3.
As a replacement for chilled
water
4.
NEVER
What is the maximum permissible
chloride that may be used in
cooling system water?
1.
6.5 epm
2.
0.65 epm
3. 0.065 epm
4.
0.0065 epm
What is an indication that the
1-41.
1-42.
1-43.
1-44.
1-45.
1-46.
1-47.
duplex strainer is clogged?
1.
The pressure reading will be 5
to 10 psi below a clean basket
reading
2. The pressure reading will be 5
to 10 psi above the clean
basket reading
3. The water temperature will be 5
to 10 degree below normal
4.
The water temperature will be 5
to 10 degree above normal
If the pressure drop is less than
that of a clean basket reading, the
basket may be missing.
1.
True
2.
False
The three-way temperature
regulating valve is used where
seawater is the primary cooling
medium, and the two-way valve is
used where chilled water is the
primary cooling medium.
1.
True
2.
False
The basic operation of both the
two-way temperature regulating
valve is the same as the three-way
temperature regulating valve except
that the two-way valve has a manual
override feature.
1.
True
2. False
Temperature regulating valve
corrective maintenance consists
only of visual checks for leaks and
corrosion.
1. True
2. False
Which of the following devices is
used to regulate flow in a seawater
cooling system?
1.
The gate valve
2. The globe valve
3. The orifice plate
4.
The relief valve
Which of the following flow
regulators is used to regulate flow
in the chilled water system?
1.
The globe valve
2.
The orifice plate
3. The variable orifice
4. The equipment-flow regulator
4